Device for Explosion Protection in closed volumes operating at low vacuum pressures based on the liberation the overpressure of explosion to safe area, avoiding that the design resistance of the equipment is exceeded.
Technical details
Type | Rectangular, Domed |
Dimensions | from 250 up to 1220 mm |
Material | AISI 304 or 316 |
Efficiency | 100% |
Bursting pressure | 20 to 500 mbar |
Tolerance | +/-25% |
Max. Working Pressure | 60% Pstat |
Support vacuum pressure | -100 mbar |
Max. Working Temperature | up to 350ºC |
Product | Gas by Group IIA and organic and metallic dust St3 |
Marking | Ex GD |
ATEX Certification | according to EN14797:2006 y EN14994:2007 |
Dimensions
Reference | External Dimensions (mm) | Internal Dimensions (mm) | Effective Venting Area |
---|---|---|---|
Reference | External Dimensions (mm) | Internal Dimensions (mm) | Effective Venting Area |
BRD550x250 | 550×250 | 480×180 | 0,086 |
BRD537x385 | 537×385 | 467×315 | 0,147 |
BRD670x570 | 670×570 | 600×500 | 0,300 |
BRD880x530 | 880×530 | 810×460 | 0,373 |
BRD1000X666 | 1000×666 | 930×596 | 0,554 |
BRD1000x1000 | 1000×1000 | 930×930 | 0,865 |
For other sizes and/or working conditions please consult us
Accesories
Magnetic Break Detector MK500A ATEX approval Ex II 3D IIIC t125ºC Dc X Possibility of mounting on different types of cylinders. Detection range: Reaction sensitivity [mT] 2 Accuracy: Variations Hysteresis [mm] 1 Temperature: -25ºC to 60ºC Breakage signalling cable type RECS for high temperature VP2759 Working temperature: -60ºC to 300ºC Peak temperature: 350ºC AWG: 20S Nominal duct diameter: 0,965 mm Total length: 2m Weather insulation for vent panelsProtection against inclement weather. Reaction to fire A1: Non-combustible according to Euroclasses (EN 13501-1) Operating temperature limit 700ºC Material: Inox + Rock Wool
Welded (L) or screwed (U) AISI 304 and AISI 316 Vertical (Interior Reinforcement) and Horizontal Installation Note: Mounting flanges only for cirular panels, the rest is mounted on paper. Please consult us if you need other solution. Outdoor tarpaulin Tarpaulin to protect the panels outdoors. Protects the panels from adverse weather conditions such as rain or snow. EPDM seal Dynamic rubber strip prevents vibration between compact materials. It acts as an air, water and dust sealing gasket, both for exteriors and interiors. Resistant to ultraviolet rays and extreme temperatures. Temperature from -30ºC to 90ºC .
High Temperature Ceramic Process Seal Stability at high temperatures up to 1100ºC Meets European regulatory requirements. Excellent wetting resistance of molten aluminum. Low thermal conductivity. Flexibility. Easy to wrap, shape or cut. Loctite SI 5900; Temperature up to 275ºC in continuous.
Silicone Process Seal Temperature from -40ºC to 220ºC White sponge silicone (15HS) Excellent temperature resistance. Good resistance to chemicals. Great capacity of recovery to the compression Good flexibility at low temperatures.
Downloads
Data Sheet PDF Paneles de Vento – ENG Ficha técnica PDF – Paneles de Vento – ESP Ficha técnica PDF – Paneles de Vento – GER
Send us a message and we will contact you as soon as possible
Pol. Industrial Los Portales, c/ Hojalateros, P03
13700 Tomelloso, Ciudad Real, España
Producto
Disponibilidad salvo previa venta
Precio
Cantidad
Producto
Disponibilidad salvo previa venta
Precio
Cantidad
Explosion Vent Panels Domed [BRD]
20 years of experience at your service in protection
consulting and training in Explosive Atmospheres
Personalized assistance in more than 30 countries.
Our customer service works to offer you the best solution.
Shipping.For more information here
Worldwide shipping.
Insurance included and return guarantee
Ask our sales team without obligation.
News on your company's protection
Be the first to know when new products are launched