NOVEx II – Flap Isolation Valve

The NOVEx II flap valve is a mechanical isolation system designed to stop the spread of an explosion through process ducts, protecting the rest of the facility.

The NOVEx II Flap Valve is a passive mechanical isolation system designed to stop the spread of an explosion through process ducts, protecting the rest of the facility.

During a deflagration, the overpressure generated pushes the flapper, which closes instantly and blocks the passage of flame and combustion gases, preventing them from reaching equipment located upstream, such as silos, cyclones or filters.

The NOVEx II can be installed in horizontal or vertical ducts (up to 90°), both in pressure (“push”) and suction (“pull”) applications. Its compact design makes it easy to integrate into tight spaces, and its normally open flap configuration significantly reduces pressure loss during normal system operation.

It is available with a wide range of accessories that allow you to monitor its operating status and ensure reliable performance over time: position sensors, wear, dust accumulation and automatic cleaning system.

  • Product Type: All types of powder, including organic and metallic. Kst ≤ 305 bar-m/s, Pmax ≤ 9.2 bar, WED ≥ 1 mJ, MIT ≥ 110 °C
  • Material: painted carbon steel / AISI 304, AISI 316 or AISI 310 stainless steel / wear-resistant steel
  • Dimensions: DN 100 to DN 1250
  • Flange: according to DIN 24154/R2, T2
  • Installation: horizontal, vertical, inclined
  • Mounting: PULL or PUSH
  • Elbows on the device: maximum 3, maximum 90°, minimum radius-to-diameter ratio 0.65
  • Protected side distance: minimum 5xD (diameter) in a straight line (m)
  • Working temperature: from -20ºC (to ensure that the product does not freeze) to +90ºC (consult for other temperatures).
  • Airflow (in PUSH): 100 ≤ DN ≤ 500: 18 m/s // 500 < DN ≤ 1250: 10 m/s
  • Dust concentration: maximum 500 g/m3
  • Certification: EN16447 and EN15089. NFPA 69 Compatibility (to comply with NFPA 69, there are special considerations. Contact us.)
  • ATEX marking: Ex II D EN 16447. LOM 22ATEX1035X
Reference
Diameter (mm)
External Dimensions (mm)
  • NOVExII100
    100
    275x276x689x101
  • NOVExII112
    112
    275x276x689x113
  • NOVExII125
    125
    275x276x689x126
  • NOVExII140
    140
    275x276x689x141
  • NOVExII150
    150
    275x276x389x151
  • NOVExII160
    160
    285x286x391x161
  • NOVExII180
    180
    306x306x395x181
  • NOVExII200
    200
    326x326x399x201
  • NOVExII224
    224
    251x350x403x225
  • NOVEXII250
    250
    377x376x408x251
  • NOVExII280
    280
    408x406x414x281
  • NOVExII300
    300
    429x426x418x301
  • NOVExII315
    315
    444x441x420x316
  • NOVExII355
    355
    486x481x428x356
  • NOVExII400
    400
    532x526x436x401
  • NOVExII450
    450
    584x576x450x451
  • NOVExII500
    500
    638x626x473x501
  • NOVExII560
    560
    700x686x544x561
  • NOVExII600
    600
    741x726x580x601
  • NOVExII630
    630
    773x756x607x631
  • NOVExII710
    710
    856x836x679x801
  • NOVExII800
    800
    949x926x759x801
  • NOVExII900
    900
    1053x1026x849x901
  • NOVExII1000
    1000
    1157x1126x939x1001
  • NOVExII1120
    1120
    1281x1246x1046x1121
  • NOVExII1250
    1250
    1416x1376x1163x1251

For other sizes and/or working conditions please contact Adix

Do you have any questions?

Write to us and our technical team will answer you.