The automatic cleaning system keeps the inside of the NOVEx valve free of dust buildup by periodically running compressed air injection cycles.

The automatic cleaning system keeps the inside of the NOVEx valve free of dust buildup by periodically running compressed air injection cycles. This extends the intervals between manual cleanings and ensures proper flap operation in environments with a high dust load.

Recommended for installations with abrasive material or very dusty processes, where it is critical to prevent obstructions in valve closure.

  • Recommended operating pressure: 87–116 psig (6–8 bar) (max. 174 psig / 12 bar)
  • Maximum flow rate: 9.2 ft³/h (0.26 m³/h)
  • Pneumatic connection: Ø 0.31″ (8 mm)
  • Adjustable cycles: interval between injections 0.5 to 45 min + injection duration 0.5 to 10 s
  • Power supply: 24 V DC / max. 1 A
  • Degree of protection: IP65
  • Temperature range: 14 °F to +122 °F (-10 °C to +50 °C)
  • ATEX marking: II 2D