TES-01 IP Control Unit

When the grounding clamp is connected to the vehicle’s connection point, the system measures the electrical resistance between the clamp and the control unit to verify that a conductive circuit has been formed.

When the grounding clamp is connected to the vehicle’s connection point, the system measures the electrical resistance between the clamp and the control unit to verify that a conductive circuit has been formed. If the resistance is low enough, the TES-01 V2 allows electrostatic charges to dissipate safely to ground, preventing sparks.

The system then checks the electrical capacitance at the connection point. Only if it matches that of a tanker truck does the green status light come on and loading or unloading is enabled. If the connection is lost or continuity is interrupted, the system switches to a red status signal and stops the operation through an interlock relay.

  • ATEX zones of use: 21 and 22 (dust) and non-hazardous areas
  • Certificate: ITS14ATEX17966X
  • Marking: II 2 (1)D Ex tb [ia Da] IIIC T135 °C Db
  • Material: steel with aluminum front
  • Dimensions (H x W x D): 11.8″ x 7.9″ x 3.1″ (300 x 200 x 80 mm)
  • Weight: 11 lb (5 kg)
  • Connections: 3 entries for M20 cable glands
  • Cable glands: Ex t with a clamping range of 0.20″-0.39″ (5-10 mm)
  • External grounding screw: M8, length 0.67″ (17 mm)
  • Protection class: IP 66
  • Power supply: 100-240 V AC 50/60 Hz or 24 V DC (see also installation conditions)
  • Power consumption: 20 W
  • Operating temperature: -4 °F to +104 °F (-20 °C to +40 °C)
  • Relative humidity: 95% at 68 °F (20 °C), non-condensing

Have a question?

Contact us and our engineering team will get back to you.